Single Phase Industrial Online Tower Type UPS Uninterruptible Power Supply
PRODUCT FEATURES
Fully digital-controlled thyristor rectification and IGBT inverter technology;
Online single-input single-output double-conversion structure with soft-start function;
Utilizes output isolation transformer technology;
Supports 200, 220, 230, 240Vac, 50/60Hz grid systems;
Wide input voltage and frequency range:
Single-phase: 160-280Vac
Three-phase: 286-475Vac;
Strong load adaptability and output overload/short-circuit protection capabilities. Uses buffering technology and peak current protection to handle 0-100% load steps without transferring to bypass;
Selectable output voltage and frequency;
System efficiency exceeds 85%. In ECO mode, energy conversion efficiency reaches 98% with significant energy savings;
Supports masterless redundant parallel operation of multiple units, with parallel circulating current ≤5%;
Intelligent charging design: Alerts and protects against excessively low/high battery voltage. Provides real-time battery diagnostics and data feedback;
Uses a 2.4/2.8-inch color dot-matrix LCD + LEDs + keypad to intuitively display UPS operational status, parameters, alerts, and temperature control. User-friendly operation;
On display panel:
Configurable battery test modes
Battery runtime calculation
UPS operation mode settings
Intelligent fault diagnostics
Historical event/error log query
Fault cause analysis via error records;
LAN/WAN remote monitoring via SNMP network adapter. Interfaces: RS232, USB, EPO;
Front-to-rear airflow design improves installation environment and reduces failure rates;
Compact size, powerful functionality, and easy maintenance compared to similar products.
SECURITY AND STABILITY
Adopts a microprocessor to implement fully digital control over all power conversion stages of the UPS, enhancing system consistency and stability;
Utilizes a controlled rectifier design to significantly improve adaptability to grid power, making the inverter safer and more reliable;
Built-in output isolation transformer reduces the impact of neutral-to-ground voltage and load harmonic currents on the inverter;
Independent battery terminals prevent critical failures caused by installation errors, greatly reducing operational risks;
Over 90% of components in the system design are internationally renowned brands. Equipment undergoes 24-hour aging and validation tests before leaving the factory, ensuring high system reliability.
| Model |
H6K(L) |
H10K(L) |
H20K(L) |
| Phase |
single in single out |
| Capacity |
6KVA/4.8KW |
10KVA/8KW |
20KVA/16KW |
| INPUT |
| Input Voltage |
208VAC/220VAC/230VAC |
| Voltage Range |
165~285VAC |
| Frequency Range |
50Hz±1% |
| OUTPUT |
| Output Voltage |
208VAC/220VAC/230VAC |
| Voltage Accuracy |
±1% |
| Freq. Range (Synchronized) |
45Hz~55Hz to 55Hz~64Hz |
| Freq. Range (Battery Mode) |
50Hz ±0.1Hz to 60Hz ±0.1Hz |
| THD (Total Harmonic Dist.) |
<3% (Linear Load), <5% (Non-Linear Load) |
| Transfer Time |
Utility to Battery |
0ms |
| Transfer Time |
Inverter to Bypass |
0ms |
| Efficiency |
>88.3% |
| BATTERY |
| BATTERY (Standard Unit) |
Battery Model |
12V / 9Ah |
| Quantity |
16pcs |
| Recharge Time (90% Cap.) |
Restore to 90% capacity in 6 hours |
| Max. Charging Current |
2A |
| Charging Voltage |
218VDC±1% |
| BATTERY (Extended Unit) |
Battery Model |
Refer to applier |
| Quantity |
16 (16-20 adjustable) |
| Charging Voltage |
218.4V+1% |
245.7 V+1% |
245.7 V+1% |
| DISPLAY |
| LCD Information |
UPS status, Load %, Battery %, Input/Output Voltage, Runtime, Fault Alarms |
| PHYSICAL (Standard Unit) |
Dimensions (D×W×H mm) |
635×610×220 |
N/A |
| Net Weight (kg) |
84 |
|
| PHYSICAL (Extended Unit) |
Dimensions (D×W×H mm) |
475×610×220 |
790×645×310 |
800x665x390mm |
| Net Weight (kg) |
44 |
60 |
70 |
| ENVIRONMENT |
| Operating Temperature |
0-40℃ |
| Relative Humidity |
<95% (non-condensing) |
| Noise Level |
<60dB @ 1 meter |
| CONTROL & MANAGEMENT |
| Communication Ports RS-232/USB |
Win 2000/2003/XP/Vista/2008/7/8/10, Linux, Mac |
| Optional SNMP |
Supports SNMP power management |