Add to Cart
LiFP Series Lithium Battery System For UPS
System Voltage Level
512VDC
System Battery Capacity
50Ah/100Ah
Application Fields
Widely used in communication, finance, government, education, transportation, industry and commerce, taxation, medical treatment, energy, electric power, UPS power supply, and energy storage systems, etc., which are large-scale backup power and energy storage scenarios.
Performance Features
Mainstream lithium iron phosphate cell, safe and reliable, longer cycle life;
Higher volume energy ratio and weight energy ratio, reducing the rental cost of installation sites;
Supports multi-cluster system parallel connection, improving system output power and extending backup power storage time;
Modular design, making installation and maintenance more convenient and quick;
High-performance BMS management system, with multi-state monitoring and alarm management for more comprehensive protection.
Parameters
Model | LiFP512V100-N1 | LiFP512V050-N1 |
System Rated Capacity | 100AH | 50AH |
System Rated Voltage | 512VDC | 512VDC |
System Voltage Range | 400-576VDC | 400-576VDC |
System Backup Time | ≥15 minutes | ≥15 minutes |
Maximum Discharge Current | 400A (4C) | 200A (4C) |
System Rated Energy | 51.2kWh | 25.6kWh |
System Nominal Power | 51.2kW | 25.6kW |
System Maximum Output Power | 204.8kW | 102.4kW |
System Maximum Parallel Connection Support | 1 master cabinet + 10 slave cabinets | 1 master cabinet + 10 slave cabinets |
System Composition Cluster Number | 1 | 1 |
Total Number of System Cabinets | 1 | 1 |
System Cabinet Wiring Method | Top entry and exit wiring | Top entry and exit wiring |
System Total Dimensions (WDH) mm | 60010002000 | 6008002000 |
System Reference Weight (kg) | 798 | 456 |
Working Temperature | Discharge: -20℃~50℃, Recommended 5℃~40℃ Charging: 0℃~45℃, Recommended 15℃~30℃ | Discharge: -20℃~50℃, Recommended 5℃~40℃ Charging: 0℃~45℃, Recommended 15℃~30℃ |
Altitude | Over 2500 meters, special explanation required | Over 2500 meters, special explanation required |
Communication Method | CAN/RS 485 | CAN/RS 485 |
Fire Protection Requirements | FM200 (optional)/ aerosol (optional) | FM200 (optional)/ aerosol (optional) |
Protection Level | IP20 | IP20 |
BMS | Lithium-ion BMS has protection functions for current, voltage, temperature, etc., supports overvoltage, undervoltage, overcurrent, high and low temperature, abnormal collection alarm protection, and uploads alarm and status data | Lithium-ion BMS has protection functions for current, voltage, temperature, etc., supports overvoltage, undervoltage, overcurrent, high and low temperature, abnormal collection alarm protection, and uploads alarm and status data |